CVE-2023-25915 — Danfoss AK-SM 800A Series Improper Input Validation Vulnerability
Description
Danfoss AK-SM 800A Series contains an improper input validation vulnerability that could allow a remote attacker to run arbitrary commands on the affected system.
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Notes
https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2023-08-01 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2023-25915
Executive AI analysis
Plain-English summary
A critical input validation vulnerability in Danfoss AK-SM 800A commercial refrigeration and energy management controllers allows remote attackers to execute arbitrary commands. This gives malicious actors direct, unauthorized command-line access to control hardware responsible for supermarket cooling, energy optimization, and facility management without requiring physical access.
Business impact
Successful exploitation can lead to physical disruptions, including the failure or shutdown of cold-chain refrigeration systems, leading to substantial inventory spoilage, financial losses, regulatory penalties, and facility downtime. Compromised devices also serve as persistent footholds for attackers seeking to pivot into broader enterprise and operational networks.
Cloud / AWS relevance
While the AK-SM 800A is an on-premises edge IoT device, many retail enterprises connect these controllers to AWS-hosted monitoring systems, analytics platforms, or data lakes using AWS IoT Core or site-to-site VPNs. Attackers compromising an on-premise unit could attempt to extract AWS API keys, leverage trust relationships, or disrupt telemetry streams feeding AWS cloud applications.
Recommended action
Immediately apply the firmware patch or mitigations specified in Danfoss security advisory DSA-2023-08-01. Ensure these industrial management systems are strictly isolated from the public internet using dedicated OT VLANs and firewalls, and perform forensic triage on any previously exposed controllers following CISA BOD 26-04 guidelines.
Need help remediating this vulnerability?
Our team helps organizations patch, mitigate, and respond to CISA KEV advisories fast.